Other measuring devices
Produkte filtern
–
Extraction thimbles MN 645, pure cellulose
Height: 40 mm | Int. Ø: 8 mm | Manufacturer Article Number: 645001 | Material: Cellulose | Type: MN 645 | UNSPSC: 41104817 | Wall thickness: 1,0 mm
Fat determination in food and feedDetermination of binder content in asphaltAnalysis of soil contaminantsDetermination of additives in rubber and elastomers
Produktnummer: 645001-4001244
Hersteller: Macherey-Nagel GmbH & Co. KG
Extraction thimbles MN 645 W, cellulose
Height: 80 mm | Int. Ø: 20 mm | Manufacturer Article Number: 645105 | Material: Cellulose | Type: MN 645 W | UNSPSC: 41104817
Extraction thimbles are used for holding solid materials, from which certain substances are to be extracted with a suitable solvent. Additionally, extraction thimbles are used in the fields of air and waste gas analysis for collecting solid particles. More permeable than MN 645.
Produktnummer: 645105-4001264
Hersteller: Macherey-Nagel GmbH & Co. KG
Extraction thimbles MN 645 D, cellulose
Height: 80 mm | Int. Ø: 30 mm | Manufacturer Article Number: 645220 | Material: Cellulose | Type: MN 645 D | UNSPSC: 41104817
Extraction thimbles are used for holding solid materials, from which certain substances are to be extracted with a suitable solvent. Additionally, extraction thimbles are used in the fields of air and waste gas analysis for collecting solid particles. With lid.
Produktnummer: 645220-4001267
Hersteller: Macherey-Nagel GmbH & Co. KG
Extraction thimbles MN 645 F, cellulose
Height: 80 mm | Int. Ø: 22 mm | Manufacturer Article Number: 645406 | Material: Cellulose | Type: MN 645 F | UNSPSC: 41104817
Extraction thimbles are used for holding solid materials, from which certain substances are to be extracted with a suitable solvent. Additionally, extraction thimbles are used in the fields of air and waste gas analysis for collecting solid particles. Denser than MN 645.
Produktnummer: 645406-4001270
Hersteller: Macherey-Nagel GmbH & Co. KG
Extraction thimbles MN 645 R, pure cellulose
Height: 155 mm | Int. Ø: 79 mm | Manufacturer Article Number: 645500 | Material: Cellulose | Type: MN 645 R | UNSPSC: 41104817
Extraction thimbles are used for holding solid materials, from which certain substances are to be extracted with a suitable solvent. With sealing collar and two finger recesses on opposite sides of the collar, for dust analysis in industrial gases, exhaust gases and room air.
Produktnummer: 645500-4001272
Hersteller: Macherey-Nagel GmbH & Co. KG
Extraction Thimbles MN 649, micro glass fibre
Height: 50 mm | Int. Ø: 15 mm | Manufacturer Article Number: 649103 | Material: Glass fiber (GF) | Max. temperature resistance: 500 °C | Type: MN 649 | UNSPSC: 41104817 | Wall thickness: 1,0 mm
Pollution monitoring, air samplingHigh temperature filtration (up to 500 °C)For solvents incompatible with cellulose thimbles (for example strong acids or bases)
Produktnummer: 649103-4001273
Hersteller: Macherey-Nagel GmbH & Co. KG
Acylation reagents for GC - Anhydrides
Capacity ml: 10 | Description: HFBA | GHS: GHS05 | Manufacturer Article Number: 701110.110
For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.Acylation with fluorinated acid anhydrides can be used for alcohols, phenols, carboxylic acids, amines, amino acids and steroids forming volatile, stable derivatives suited for FID as well as for ECD detection.by-products of acylation with anhydrides: corresponding acidsexcess reagent and the acid formed have to be removedHeptafluorobutyric acid anhydride (HFBA)m.w. 410.06, Bp 106 - 107°C (760mm Hg),C3F7 - CO - O - CO - C3F7density d20°/4° = 1.665Hazardous Substance DataGHSSignal wordGefahrH-SatzH314P-SatzP260sh, P280sh, P303+P361+P353, P305+P351+P338, P310SDSLink
Produktnummer: 701110.110-4001479
Hersteller: Macherey-Nagel GmbH & Co. KG
Silylation reagents - BSTFA, SILYL-991
Capacity ml: 1 | Description: BSTFA | GHS: GHS02, GHS07 | Manufacturer Article Number: 701220.201
For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.N,O-bis-trimethylsilyl-trifluoroacetamidem.w. 257.4, Bp 40°C (12mm Hg), density d20°/4° = 0.961BSTFA: R = CF3 powerful trimethylsilyl donor with approximately the same donor strength as the non-fluorinated analogue BSAadvantage of BSTFA over BSA: greater volatility of its reaction products (particularly useful for GC of some lower boiling TMS amino acids.BSTFA is nonpolar (less polar than MSTFA), and can be mixed with acetonitrile for improved solubility. For silylating fatty acid amides, hindered hydroxyls and other compounds, which are difficult to silylate (like secondary alcohols and amines), we recommend BSTFA + 1% trimethylchlorosilane (TMCS), available under the designation SILYL-991.Due to their purpose, derivatisation reagents are very reactive substances. For this reason they should be stored cool and protected from moisture.The derivatisation reagents are supplied in vials with crimp caps for easy access with a syringe. Vials with pierced sealing disks have limited stability and should be used immediately.Hazardous Substance DataGHSSignal wordAchtungH-SatzH226, H315, H319P-SatzP210, P280shUNNR3316SDSLink
Produktnummer: 701220.201-4001486
Hersteller: Macherey-Nagel GmbH & Co. KG
Silylation reagents - MSTFA
Capacity ml: 100 | Description: MSTFA | GHS: GHS02, GHS07 | Manufacturer Article Number: 701270.12100
For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.N-methyl-N-trimethylsilyl-trifluoroacetamidem.w. 199.1, Bp 70 °C (75 mm Hg), density d20°/4° = 1.11MSTFA: R' = CF3, R" = CH3The most volatile trimethylsilyl amide available.Very strong TMS donor which does not cause any noticeable fouling of the FID burning chamber even after long-time measuring series.The already good solution characteristics can be improved by addition of submolar quantities of protic solvents (e.g. TFA for extremely polar compounds such as hydrochlorides) or pyridine (e.g. for carbohydrates).Due to their purpose, derivatisation reagents are very reactive substances. For this reason they should be stored cool and protected from moisture.The derivatisation reagents are supplied in vials with crimp caps for easy access with a syringe. Vials with pierced sealing disks have limited stability and should be used soon.Hazardous Substance DataGHSSignal wordAchtungH-SatzH226, H302, H315, H319P-SatzP210, P264W, P280sh, P301+P312, P330SDSLink
Produktnummer: 701270.12100-4001492
Hersteller: Macherey-Nagel GmbH & Co. KG
Alkylation reagents for GC - Trimethylsulphonium hydroxide
Capacity ml: 10 | Description: TMSH | GHS: GHS02, GHS06, GHS07, GHS08 | Manufacturer Article Number: 701520.510 | Safety Data Sheet: https://sds.llg.de/?s=1&artnr_manuals=4001512
For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.TMSH (0.2 M in methanol) M.G. 94.06Hazardous Substance DataGHSSignal wordGefahrH-SatzH225, H301, H311, H331, H370P-SatzP210, P233, P260sh, P261sh, P280sh, P301+P310, P302+P352, P304+P340, P311, P312, P403+P233, P405UNNR3316SDSLink
Produktnummer: 701520.510-4001512
Hersteller: Macherey-Nagel GmbH & Co. KG
Alkylation kit
Content: 3x1 ml each for TMSH, DMF-DMA | GHS: GHS02, GHS06, GHS07, GHS08 | Manufacturer Article Number: 701951
For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.Which is the proper reagent for methylation?Test kit for determination of the optimum alkylation.Hazardous Substance DataGHSSignal wordGefahrH-SatzH225, H301, H302, H311, H315, H319, H331, H335, H370P-SatzP260sh, P280sh, P302+P352, P311, P405SDSLink
Produktnummer: 701951-4001513
Hersteller: Macherey-Nagel GmbH & Co. KG
Derivatisation method development kit
Content: 2 x 1 ml each for TMSH, MSTFA, MBTFA | GHS: GHS02, GHS05, GHS06, GHS07, GHS08 | Manufacturer Article Number: 701952
For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.Which type of derivatisation is best suited for your sample (alkylation, silylation or acylation)? Test kit for determination of the optimum derivatisation.Hazardous Substance DataGHSSignal wordGefahrH-SatzH225, H226, H301, H302, H311, H314US, H315, H319, H331, H370P-SatzP260D, P260sh, P280sh, P302+P352, P303+P361+P353, P305+P351+P338, P311, P405, P501SDSLink
Produktnummer: 701952-4001514
Hersteller: Macherey-Nagel GmbH & Co. KG
VarioPrep guard column holders and replacement parts
Description: VP guard column holder 8 mm for VarioPrep columns with 8 and 10 mm ID | Manufacturer Article Number: 718251
VarioPrep columnscolumn system for preparative HPLC manufactured from stainless steel with two adjustable end fittings, allows compensation of a dead volume, which could result at the column inlet after some time of operation, without need for opening the column, packed with NUCLEODUR® and NUCLEOSIL® spherical silica.O-rings available on request.
Produktnummer: 718251-4002176
Hersteller: Macherey-Nagel GmbH & Co. KG
Accessories and replacement parts for EC columns
Description: 1/16” end cap, plastic | Manufacturer Article Number: 718582
Analytical column system manufactured from stainless steel M 8 outer threads on both ends combination of sealing element and very fine-meshed stainless steel screen, PTFE sealing ring and fitting adaptor column heads SW 12 with inner threads M8 x 0,75 and UNF 10-32, as built -in guard columns use ChromCart® guard column cartridges with 8mm length with the guard column adaptor EC, packed with NUCLEODUR® spherical silica.
Produktnummer: 718582-4002178
Hersteller: Macherey-Nagel GmbH & Co. KG
Glass Wool, quartz wool, glass fiber wadding
Description: very fine fibers | GHS: GHS08 | Manufacturer Article Number: 718587 | Type: Quartz wool | UNSPSC: 23-15-18-16 | Weight g: 25
Glass wool, quartz wool and glass fiber wadding are, e.g., used for GC liners, packed GC columns etc.Hazardous Substance DataGHSSignal wordAchtungH-SatzH373P-SatzP260sh, P280shSDSLink
Produktnummer: 718587-4002181
Hersteller: Macherey-Nagel GmbH & Co. KG
NUCLEOGEL® SUGAR 810 Ca
Eluent in column: Demineralised water | Endcapped: No | Int. Ø: 7.8 mm | Length: 300 mm | Manufacturer Article Number: 719570 | Max. temperature resistance: 90 °C | Method: Analytical | Particle type: Fully porous | USP listing: L19 | Volume column: 14.3 ml
Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyValco type columns for separation of mono-, di- and oliogosaccharides - USP L19 eluent in column water.
Produktnummer: 719570-4002274
Hersteller: Macherey-Nagel GmbH & Co. KG
Guard columns for NUCLEOGEL® SUGAR 810 Ca columns
Eluent in column: Demineralised water | Endcapped: No | Int. Ø: 4 mm | Length: 30 mm | Manufacturer Article Number: 719571 | Material column: Stainless steel | Max. temperature resistance: 90 °C | Method: Analytical | Particle type: Fully porous | USP listing: L19
Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyThis guard columns require the CC column holder 30 mm.
Produktnummer: 719571-4002275
Hersteller: Macherey-Nagel GmbH & Co. KG
NUCLEOGEL® SUGAR 810 H
Eluent in column: Sulphuric acid | Endcapped: No | Int. Ø: 7.8 mm | Length: 300 mm | Manufacturer Article Number: 719574 | Max. temperature resistance: 90 °C | Method: Analytical | Particle type: Fully porous | USP listing: L17 | Volume column: 14.3 ml
Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyValco type columns for separation of sugars, sugar alcohols and organic acids - USP L17 eluent in column 0.01 N H2SO4
Produktnummer: 719574-4002276
Hersteller: Macherey-Nagel GmbH & Co. KG
Guard columns for NUCLEOGEL® SUGAR 810 H columns
Eluent in column: Sulphuric acid | Endcapped: No | Int. Ø: 4 mm | Length: 30 mm | Manufacturer Article Number: 719575 | Material column: Stainless steel | Max. temperature resistance: 90 °C | Method: Analytical | Particle type: Fully porous | USP listing: L17
Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyThis guard columns require the CC column holder 30 mm.
Produktnummer: 719575-4002277
Hersteller: Macherey-Nagel GmbH & Co. KG
EC analytical columns NUCLEOSIL® 100-5 C18 PAH, 5 µm
Eluent in column: Acetonitrile/water | Endcapped: Yes | Int. Ø: 3.0 mm | Length: 250 mm | Manufacturer Article Number: 720117.30 | Material column: Stainless steel | Max. temperature resistance: 60 °C | Method: Analytical | Particle size: 5 µm | Particle type: Fully porous | Separation system: Reverse phase | USP listing: L118 | Volume column: 1.75 ml | pH stability: 2 ... 8
Special octadecyl phase for PAH analysis.Base material NUCLEOSIL® silica, particle size 5 µm, pore size 100 Å; polymeric coating - USP L1; eluent in column acetonitrile/water 70:30; allows efficient gradient separation of the 16 PAH in accordance with EPA.Detection of the separated PAH by UV (250 to 280 nm), with diode array or with fluorescence detection at different wavelegths for excitation and emission (acenaphthylene cannot be analysed with fluorescence detection).Guard columns for EC columns NUCLEOSIL® 100-5 C18 PAH, 5 µm available on request.
Produktnummer: 720117.30-4002372
Hersteller: Macherey-Nagel GmbH & Co. KG
EC analytical columns NUCLEOCEL DELTA S, 5 µm
Eluent in column: n-heptane/2-propanol | Endcapped: No | Int. Ø: 4.6 mm | Length: 250 mm | Manufacturer Article Number: 720445.46 | Material column: Stainless steel | Max. temperature resistance: 40 °C | Method: Analytical | Particle size: 5 µm | Particle type: Fully porous | USP listing: L40 | Volume column: 4.15 ml | pH stability: 1 ... 9
NUCLEOCEL DELTA enantiomer separation based on cellulose derivativesBase material silica,chiral selector Cellulosetris-(3,5-dimethylphenylcarbamate) - USP L40Similar phases: Chiralcel® OD, Kromasil®, CelluCoat™, Eurocel® 01S-Type for high resolution, allows use of shorter columns (150 mm) for faster separations, pressure stability up to ~ 150 bar (2000 psi).Recommended applications: pharmaceutically active compounds, chiral pollutants (e. g. herbicides, PCB), chiral compounds in food (dyes, preservatives), chiral catalysts and bioorganic compounds.NUCLEOCEL DELTA for normal phase applications:Eluent in column n-heptane - propanol-2 (90:10, v/v), particle size 5 µm.
Produktnummer: 720445.46-4002445
Hersteller: Macherey-Nagel GmbH & Co. KG
EC analytical columns NUCLEOCEL DELTA-RP S, 5 µm
Eluent in column: Acetonitrile/water | Endcapped: No | Int. Ø: 4.6 mm | Length: 250 mm | Manufacturer Article Number: 720450.46 | Material column: Stainless steel | Max. temperature resistance: 40 °C | Method: Analytical | Particle size: 5 µm | Particle type: Fully porous | USP listing: L40 | Volume column: 4.15 ml | pH stability: 1,0 ... 9,0
NUCLEOCEL DELTA enantiomer separation based on cellulose derivativesBase material silica,chiral selector Cellulosetris-(3,5-dimethylphenylcarbamate) - USP L40Similar phases: Chiralcel® OD, Kromasil®, CelluCoat™, Eurocel® 01S-Type for high resolution, allows use of shorter columns (150 mm) for faster separations, pressure stability up to ~ 150 bar (2000 psi).Recommended applications: pharmaceutically active compounds, chiral pollutants (e. g. herbicides, PCB), chiral compounds in food (dyes, preservatives), chiral catalysts and bioorganic compounds.NUCLEOCEL DELTA-RP for reversed phase applications:Eluent in column acetonitrile - water (40:60, v/v), particle size 5 µm. Designed for use either in polar organic mode or with eluents containing high concentrations of chaotropic salts such as perchlorate.
Produktnummer: 720450.46-4002448
Hersteller: Macherey-Nagel GmbH & Co. KG
Guard column holder CC
Description: For 4 mm ID guard columns | Manufacturer Article Number: 721823 | UNSPSC: 23-15-18-16
Guard column holder, incl. nuts and ferrules.
Produktnummer: 721823-4002762
Hersteller: Macherey-Nagel GmbH & Co. KG
CHROMABOND® C18
Base material: Silica gel | Carbon content: 14.00 % | Endcapped: No | Filling quantity: 500 mg | Filter element material: PE | Manufacturer Article Number: 730003.250 | No. of packages: 5 | Package: 5 x Bag of 50 pcs | Package capacity: 50 Stück | Particle size: 45 µm | Particle type: Fully porous | Volume column: 3 ml | pH stability: 2 ... 8
Octadecyl modified silica phase for SPE, not endcappedBase material silica, pore size 60 Å, particle size 45 µm for C18, specific surface 500 m²/g, pH stability 2 to 8 octadecyl phases, not endcapped, carbon content 14 % possesses more free silanols (SiOH), which allow secondary interactions with polar groups of the analytes.Recommended applications: non-polar compounds, pesticides.
Produktnummer: 730003.250-4003433
Hersteller: Macherey-Nagel GmbH & Co. KG